Heat outputs are measured at ∆T 50˚C for newer boilers and shown at ∆T 30˚C, suitable for most heat pumps.
To Calculate radiator length, multiply the number of sections by the width of the section and add 24 (to account for the radiators end caps)
/s= Per Section
| Depth (mm) |
66 |
|
Section Width (mm) |
46 |
| Height (mm) |
BTU Output/s ∆T 50˚C |
Watts/s ∆T 50˚C
|
BTU Output/s ∆T 30˚C |
Watts/s ∆T 30˚C |
| 207 |
59.68 |
17.50 |
32.40 |
9.50 |
| 300 |
87.30 |
25.60 |
47.40 |
13.90 |
| 400 |
112.53 |
33.00 |
61.11 |
17.92 |
| 500 |
136.74 |
40.10 |
74.24 |
21.77 |
| 600 |
160.61 |
47.10 |
87.23 |
25.58 |
| 656 |
173.91 |
51.00 |
94.42 |
27.69 |
| 750 |
196.42 |
57.60 |
106.66 |
31.28 |
| 900 |
232.22 |
68.10 |
126.10 |
36.98 |
| 1000 |
256.43 |
75.20 |
139.23 |
40.83 |
| 1200 |
305.20 |
89.50 |
165.73 |
48.60 |
| 1500 |
379.87 |
111.40 |
206.27 |
60.49 |
| 1800 |
457.28 |
134.10 |
248.32 |
72.82 |
| 2000 |
510.82 |
149.80 |
277.37 |
81.34 |
| 2200 |
565.72 |
165.90 |
307.17 |
90.08 |
| 2500 |
650.97 |
190.90 |
353.48 |
103.66 |